30/60 Installation
Bosch Rexroth AG, A15VSO/A15VLO Series 11, RE 92801-01-B/11.2018
Table 10: Inside-reservoir installation
Installation position Air bleed Filling
4 (drive shaft horizontal) T
1
the housing oftheaxial piston
unit istobefilled using T
1
before
attachment ofthepiping
5 (drive shaft vertically up) T
2
the housing oftheaxial piston
unit istobefilled using T
2
before
attachment ofthepiping
7.3.3 Above-reservoir installation
Above-reservoir installation means that the axial piston unit isinstalled above the
minimum fluid level ofthereservoir.
To prevent the axial piston unit from draining, aheight difference h
ESmin
ofat least
25mm atport T
2
isrequired ininstallation position7.
Observe the maximum permissible suction heighth
Smax
= 800mm.
Thepermissible suction heighth
S
isderived from the total pressure loss.
6 7
h
t min
h
min
h
S max
SB
F
T
1
T
2
T
3
S
h
ES min
SB
h
t min
F
h
min
h
S max
T
1
T
2
T
3
S
Fig. 11: Above-reservoir installation A15VSO/A15VLO with installation position 6–7
T
1
,
T
2
,
T
3
Highest drain port h
t min
Minimum required immersion depth
(200mm)
F Filling/air bleeding h
min
Minimum required distance toreservoir
bottom (100mm)
S Suction port h
ES min
Minimum height required toprevent
axial piston unit from draining (25mm)
SB Baffle (baffle plate) h
S max
Maximum permissible suction height
(800mm)
Port F ispart oftheexternal piping and must beprovided onthe customer side
tomake filling and air bleeding easier.
Table 11: Above-reservoir installation
Installation position Air bleed Filling
6 (drive shaft horizontal) F T
1
(F)
7 (drive shaft vertically up) F T
2
(F)