EasyManua.ls Logo

Bosch Rexroth A15VSO - Above-Reservoir Installation

Bosch Rexroth A15VSO
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30/60 Installation
Bosch Rexroth AG, A15VSO/A15VLO Series 11, RE 92801-01-B/11.2018
Table 10: Inside-reservoir installation
Installation position Air bleed Filling
4 (drive shaft horizontal) T
1
the housing oftheaxial piston
unit istobefilled using T
1
before
attachment ofthepiping
5 (drive shaft vertically up) T
2
the housing oftheaxial piston
unit istobefilled using T
2
before
attachment ofthepiping
7.3.3 Above-reservoir installation
Above-reservoir installation means that the axial piston unit isinstalled above the
minimum fluid level ofthereservoir.
To prevent the axial piston unit from draining, aheight difference h
ESmin
ofat least
25mm atport T
2
isrequired ininstallation position7.
Observe the maximum permissible suction heighth
Smax
= 800mm.
Thepermissible suction heighth
S
isderived from the total pressure loss.
6 7
h
t min
h
min
h
S max
SB
F
T
1
T
2
T
3
S
h
ES min
SB
h
t min
F
h
min
h
S max
T
1
T
2
T
3
S
Fig. 11: Above-reservoir installation A15VSO/A15VLO with installation position 6–7
T
1
,
T
2
,
T
3
Highest drain port h
t min
Minimum required immersion depth
(200mm)
F Filling/air bleeding h
min
Minimum required distance toreservoir
bottom (100mm)
S Suction port h
ES min
Minimum height required toprevent
axial piston unit from draining (25mm)
SB Baffle (baffle plate) h
S max
Maximum permissible suction height
(800mm)
Port F ispart oftheexternal piping and must beprovided onthe customer side
tomake filling and air bleeding easier.
Table 11: Above-reservoir installation
Installation position Air bleed Filling
6 (drive shaft horizontal) F T
1
(F)
7 (drive shaft vertically up) F T
2
(F)