Installation 33/60
RE 92801-01-B/11.2018, A15VSO/A15VLO Series 11, BoschRexrothAG
4. Remove dirt and foreign particles from the installation location.
5. Install the coupling onthe output shaft ofthedrive motor inaccordance with the
specifications provided bythecoupling manufacturer.
Do not fasten down the axial piston unit until the coupling has been correctly
installed.
6. Fasten the axial piston unit attheinstallation location.
7. Align the drive shaft oftheaxial piston unit and the output shaft ofthedrive
motor sothere isno angular deviation.
8. Make sure noexcessive axial and radial forces are acting onthe drive shaft.
9. For bell housing installation, check the coupling axial play through the bell
window according tothe manufacturer's specifications.
10. Details onthe required tools and tightening torques for the mounting bolts are
available from the machine/system manufacturer.
11. When using elastic couplings, check that the drive does not resonate after
completing the installation.
7.4.5 Installation on a gearbox
The following describes how toinstall the axial piston unit ona gearbox.
After installing ona gearbox, the axial piston unit iscovered and isdifficult toaccess:
▶ Before installing, make sure that the spigot diameter centers the axial piston unit
(observe tolerances) and that noexcessive axial orradial forces are acting onthe
drive shaft oftheaxial piston unit (installation length).
▶ Protect the drive shaft against frictional corrosion byproviding permanent
lubrication.
▶ Fasten the axial piston unit attheinstallation location.
Nogearing forces higher than the permissible axial and radial forces should act
onthe shaft; ifnecessary, support the gear wheel atthegearbox output separately.
For attachment via gear
wheel orhelical gear shaft