54/60 Troubleshooting
Bosch Rexroth AG, A15VSO/A15VLO Series 11, RE 92801-01-B/11.2018
Table 15: Axial piston unit malfunction table
Malfunction Possible cause Remedy
No orinsufficient flow Insufficient air bleeding ofthehydraulic system Fill the axial piston unit, suction line for the
hydraulic pump and the reservoir
Completely air bleed the axial piston unit and
hydraulic system
Faulty mechanical drive (e.g.defective coupling) Contact machine/system manufacturer
Drive speed too low Contact machine/system manufacturer
Insufficient suction conditions, e.g.insufficient
dimensioning ofthesuction line, viscosity
ofthehydraulic fluid too high, suction height
too high, suction pressure too low, foreign
particles inthe suction line, impermissible filter
inthe suction line
Machine/system manufacturer: Check the
system, e.g.optimize inlet conditions, use
suitable hydraulic fluid
Fill the suction line with hydraulic fluid
Remove foreign particles from the suction line
Hydraulic fluid not inoptimal viscosity range Machine/system manufacturer:
Check temperature range and use suitable
hydr
aulic fluid
Insufficient pilot pressure orcontrol pressure Check pilot pressure orcontrol pressure
Contact BoschRexrothService
Malfunction ofthecontrol device orcontroller
oftheaxial piston unit
Contact BoschRexrothService
Control ofthecontrol device defective Check control (contact machine/system
manufacturer orBoschRexrothService)
Wear ormechanical damage tothe axial piston
unit
Replace axial piston unit
Contact BoschRexrothService