Bosch Rexroth Corp., RE-A 91610/12.2015
2 A6VM series 71 | Axial piston variable motor
Type code
Type code
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21
A6V M 0 0 / 71 A W V 0 –
Axial piston unit
01 Bent-axis design, variable, nominal pressure 6500psi (450bar), maximum pressure 7250psi (500bar)
A6V
Operating mode
02 Motor M
Size (NG)
03 Geometric displacement, see technical data on page 8 in cm
3
/rev
060 085 115 150 170 215
in in
3
/rev
3.66 5.19 7.02 9.15 10.37 13.12
Control device 060 085 115 150 170 215
04 Proportional control
hydraulic
positive control
Δp
St
=145psi (10bar)
● ● ● ● ● ● HP1
Δp
St
=365psi (25bar)
● ● ● ● ● ● HP2
negative control
Δp
St
=145psi (10bar)
● ● ● ● ● ● HP5
Δp
St
=365psi (25bar)
● ● ● ● ● ● HP6
Proportional control
electrical
positive control
U = 12 V DC
● ● ● ● ● ● EP1
U = 24 V DC
● ● ● ● ● ● EP2
negative control
U = 12 V DC
● ● ● ● ● ● EP5
U = 24 V DC
● ● ● ● ● ● EP6
Two-point control
hydraulic
negative control
‒ ‒ ‒ ● ● ● HZ5
● ● ● ‒ ‒ ‒ HZ7
Two-point control
electrical
negative control
U = 12 V DC
‒ ‒ ‒ ● ● ● EZ5
U = 24 V DC
‒ ‒ ‒ ● ● ● EZ6
U = 12 V DC
● ● ● ‒ ‒ ‒ EZ7
U = 24 V DC
● ● ● ‒ ‒ ‒ EZ8
Automatic control
high-pressure related,
Positive control
with minimum pressure
increase
Δp≤approx.145psi (10bar)
● ● ● ● ● ● HA1
with pressure increase
Δp=1450psi (100bar)
● ● ● ● ● ● HA2
Automatic control
speed related, negative
control p
St
/ p
HD
=5/100
hydr. travel direction valve ● ● ● ● ● ● DA0
electric travel direction
valve + electric V
gmax
circuit
U = 12 V DC
● ● ● ● ● ● DA1
U = 24 V DC
● ● ● ● ● ● DA2
Pressure control/override 060 085 115 150 170 215
05 Without pressure control/override
● ● ● ● ● ● 00
Pressure control fixed setting, only for HP5, HP6, EP5 and EP6
● ● ● ● ● ● D1
Override
of controls
HA1 and HA2
hydraulic remote control, proportional
● ● ● ● ● ● T3
electric, two-point
U = 12 V DC
● ● ● ● ● ● U1
U = 24 V DC
● ● ● ● ● ● U2
electric and travel
direction valve, electric
U = 12 V DC
● ● ● ● ● ● R1
U = 24 V DC
● ● ● ● ● ● R2
Connector for solenoids
1)
(see page 62)
06 Without connector (without solenoid, only for hydraulic control)
0
DEUTSCH - molded connector, 2-pin, without suppressor diode
P
●
= Available
○
= On request
‒
= Not available
1) Connectors for other electric components can deviate.