5-14 Instructions for Use Rexroth EcoDrive 03 DKC**.3-016
DOK-ECODR3-DKC16*UL***-IB01-EN-P
min. tightening torque
[Nm]
max. tightening torque
[Nm]
2.5 3.0
Fig. 5-32: Tightening torque
Cross section
single wire
[mm²]
Max. connectable
cross section
in mm²
Max. wire size
in AWG
gauge no.:
-- 25 --
Fig. 5-33: Connection cross section
Allocation
Motor
Mains
XS1, XS2, XS3 Shield Connections
XS1
Connection for shield:
Total motor cable shield
Holding brake
Motor temperature monitoring
XS2
Connection for shields of cables at X1 and those for the command
communication interfaces.
XS3
Connection for shields of cables at X3 and X10.
6 - 15 mm (for all shield connections)
Note: Always connect the shield connections of the cables
(especially of the motor cables) with a large contact surface.
H1, S1, S2, S3: Diagnostic display, Reset key, Address switch