Rexroth EcoDrive 03 DKC**.3-016 Instructions for Use 5-15
DOK-ECODR3-DKC16*UL***-IB01-EN-P
S1
• Key for resetting diagnostic displays of errors
• Key for updating firmware
S2, S3
Switch for setting the drive address.
Two decade switches are used to set the drive address. It can be set to
any number between 1 and 99.
Example:
Switch setting S3 = 9 (value of tens)
Switch setting S2 = 1 (value of ones)
Drive address = 9 * 10 + 1 = 91
Note: The address is not set at delivery.
The setting of switches S2 and S3 depends on the model,
firmware and the drive address wanted.
⇒
see functional firmware description
5.3 Installation
General Information on How to Install the Drive Controller
Damage can be caused to the drive controller or circuit boards if
electrostatic charging present in people and/or tools is discharged across
them. Therefore, please note the following information:
CAUTION
Electrostatic charges can cause damage to
electronic components and interfere with their
operational safety!
⇒
Exposed conductive parts coming into contact with
components and circuit boards must be discharged
by means of grounding. Otherwise errors may occur
when triggering motors and moving elements.
Such exposed conductive parts include:
• the copper bit when soldering
• the human body (ground connection caused by touching a conductive,
grounded item)
• parts and tools (place them on a conductive support)
Endangered components may only be stored or dispatched in conductive
packaging.
Note: Rexroth connection diagrams are only to be used for
producing installation connection diagrams. The machine
manufacturer’s installation connection diagrams must be used
for wiring the installation!
Address switch S2, S3;
Drive address