EasyManua.ls Logo

Bosch Rexroth EcoDrive 03 - X10 EcoX Expansion Interface

Bosch Rexroth EcoDrive 03
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-12 Instructions for Use Rexroth EcoDrive 03 DKC**.3-016
DOK-ECODR3-DKC16*UL***-IB01-EN-P
Basic connection of motor power, holding brake and
motor temperature monitoring
AP5387F1.FH7
AC-Motor
M
3
U1
V1
W1
X1 X2
T1
T2
U
BR-
BR+
3
4
1
2
A1 A2 A3
X6
5
6
TM+
TM-
BR+
BR-
U
B
0VB
24V
Ext
0V
Ext
DKC
XE1
X5_M
24V
XS1
Temperature
dependent resistance
Holding
brake
Fig. 5-25: Connection of motor cable, holding brake and temperature monitor
for motors with connector box
Note: The cable designations and all details on making cables are
outlined in the cable or motor document.
X10, EcoX Expansion interface
Note: EcoX allows:
synchronizing drives and I/O modules
connecting up to 2 modules with 16 digital inputs and
outputs each per drive controller
transmitting a command value from one drive controller to
a maximum of three other drive controllers
Technical description of connector
Ap5268f1.FH7
123
456
Fig. 5-26: Connector X10
Type No. of pins Design
Spring contact 2 x 3 Bushing on connector
Fig. 5-27: Design
Cross section
single wire
[mm²]
Cross section
multi core wire
[mm²]
Wire size
in AWG
gauge no.:
0.2-2.5 0.2-1.5 24-16
Fig. 5-28: Connection cross section
Illustration:
Design:
Connection cross section:

Related product manuals