Rexroth EcoDrive 03 DKC**.3-016 Instructions for Use 5-3
DOK-ECODR3-DKC16*UL***-IB01-EN-P
X1, Connections for control voltage
Technical description of connector
Ap5382f1.FH7
123
456
Fig. 5-3: Connector X1
Type No. of pins Design
Spring contact 2 x 3 Bushing on connector
Fig. 5-4: Design
Cross section
single wire
[mm²]
Cross section
multi core wire
[mm²]
Wire size
in AWG
Gauge no.:
0,2-2,5 1,5-2,5 16-12
Fig. 5-5: Connection cross section
24V control voltage supply (+24V and 0V)
AP5392F1.FH7
X1
2
5
+24V
1
0V
3
4
6
device-external device-internal
connection for control voltage
Fig. 5-6: Connections for control voltage
Voltage at X1/1 against X1/2:
Current or power consumption X1/1:
see chapter "Ratings and
Dimensions"
Reverse voltage protection: Via allowed voltage range
using internal protection
diodes
Note: Strong mechanical influence on the test tap of the terminals
can increase the transition resistance and destroy the
terminals.
Note: The input 0 V is connected directly to the device potential. The
utilization of an insulation monitoring for +24 V and 0 V against
device is therefore not possible!
wire cross section: min. 1 mm²
wire routing: parallel if possible
Max. allowed inductance between 24V source
and X1:
100 µH
(equals about 2 x 75 m)