RE 15300-WA, Version 06.2021, Bosch Rexroth AB
Installation 39/72
The cylinders should be vented from air during commisioning by using the air
bleeding screws on the cylinder, see Fig. 34 and Fig. 37
DD00079213, DD00079216
Connection Description Dimensions Remarks
T4A Pressure connection G½˝
To be connected to A on
cylinder
T4C Pressure connection G½˝
To be connected to B on
cylinder
3 Cylinder
A Pressure connection G½˝
B Pressure connection G½˝
C Air ventilation G½˝ Air lter
Fig. 38: Hydraulic connections DTCBM
Hydraulic connection between motor and hydraulic cylinder
This is valid with the hydraulic cylinder on the right hand-side of the motor.
See Fig. 38
1. Mount the hoses, The hose mounted to connection T4A has to be mounted to
the hydraulic cylinder connection (A) and the hose from connection T4C has to
be mounted to the cylinder connection (B).
2. Detail view A valid for DTCBM 4600-6000. Mount the hoses between the
cylinders. Connection A to connection A and connection B to connection B
NOTICE
Overload of driven shaft!
Damage of equipment.
▶ Make sure to follow the installation instructions regarding hydraulic
connections .
Table 14: Hydraulic connections DTCBM
A
A
B
B
C
C
Detail view A
Air bleeding A port
Air bleeding B port