Loading...
RE 15300-WA, Version 06.2021, Bosch Rexroth AB
Installation 49/72
Oil
Air
Oil lling of spline
Fig. 49: Vertical mounting of spline motor
8. Plug G ¼
8. Plug G ¼
7. Plug G ¼
5. Screw M30
DD00080051
Vertical mounting of motor
DANGER
Vertical mounted motor: Motor/ange falls down!
Risk to life and risk of injury or serious injuries and
risk of damage to equipment!
Make sure that the ange is correctly mounted to
the foundation and can withstand the weight and
forces from the motor.
Make sure the motor is correctly mounted
to the ange.
Do not stand in the danger zone!
The spline area must always be lubricated with
hydraulic oil to prevent wear of spline interface.
Wear of spline increase relative movement between driven shaft and motor,
which can cause the mounting kit, holding the motor axially, to break.
Torque arm mounted motor with spline and mounting kit can be used only for
horizontal mounting and/or motor driven shaft pointing downwards unless
extra safety arrengements is installed to secure the motor from falling.
DANGER ZONE