62/70 Disassembly and replacement
Bosch Rexroth AG, General Operating Instructions HYDROTRAC GFT 8000 series 40, RE 79022-01-B/04.2020
12.4 Preparing the planetary gearbox for storage reuse
This chapter only describes how to prepare the planetary gearbox for storage
reuse.
For queries, please contact a Rexroth's subsidiary located near you or the main
plant directly. For the addresses of our national agencies, refer to
www.boschrexroth.com and the address directory in appendix A “Address
directory” of the material number-specific operating instructions.
1 Carefully close all the openings of the planetary gearbox.
2 Clean the planetary gearbox as described in chapter 10.1 “Cleaning and Care”.
3 For preservation, fill the planetary gearbox with lubricating oil approved for this
planetary gearbox. See selection list – industrial gear oils in appendix B
"Required and supplementary documentations" in the material number-specific
operating instructions. Fill the planetary gearbox as described in chapter
8.1.3 “Filling the planetary gearbox with lubricating oil” of this operating
instructions.
4 Preserve the surfaces of external flanges, shaft ends and flange surfaces with a
preservative (e.g. PERIGOL VCI 230 or CUSTOS 10-38). Observe chapter 6.2.1
“Preservation” and the associated product data sheets and safety data sheets.
5 Store the planetary gearbox as described in chapter 6 “Transport and storage”.