R911299720 / 02 | Rexroth IndraControl VCP 25 Electric Drives and Controls | Bosch Rexroth AG 6-1
Display and Operating Components
6 Display and Operating Components
6.1 Display
The operator terminal is equipped with a STN display.
6.1.1 Setting the Contrast / Brightness
To define the contrast / brightness setting, use the programming soft-
ware to set up the system variable LcdContrast or LcdBackLight in
any mask.
In the programming software, enter the following values as lower and
upper limits for the representation type.
If you did set-up the system variable, you can set the contrast or bright-
ness as follows. Open the mask where you set up the system variable
and:
1. Press the contrast / brightness button.
2. Enter a new value for the contrast / brightness. To do so, use the
keyboard shown on the screen.
3. Confirm with Enter.
The new contrast / brightness setting becomes effective immediately
after the Enter key is pressed. If necessary, repeat steps two and three
until you are satisfied with the contrast / brightness.
Danger of intoxication!
If the display is damaged, avoid touching, swallowing or breathing in the
liquids or gases which may leak out.
Danger of corrosion!
If the display is damaged, avoid touching, swallowing or breathing in the
liquids or gases which may leak out.
To do so, follow the instructions listed in the programming software's
help topic "How do I specify the contrast / brightness setting for the op-
erator terminal".
System Variable Lower Limit Upper Limit Default Setting
LcdContrast 0 + 31 + 16
LcdBackLight 0 + 15 + 8
Fig. 6-1: Values for the representation type
If you do not configure the system variable LcdContrast or
LcdBackLight, the default setting is used when the device is initialized.

Table of Contents