EasyManua.ls Logo

Bosch Rexroth IndraControl VCP 25 - Fig. 7-8: Block Diagram Termination RS485; Fig. 7-9: Resistance Values Termination RS485; Fig. 7-10: Termination Switch

Bosch Rexroth IndraControl VCP 25
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R911299720 / 02 | Rexroth IndraControl VCP 25 Electric Drives and Controls | Bosch Rexroth AG 7-7
Interfaces
Fig. 7-8: Block diagram termination RS485
Legend for table:
I=Switch ON
-=Switch OFF
Designation Value
R1, R3 510 Ohm
R2 150 Ohm
R4 120 Ohm
Fig. 7-9: Resistance values termination RS485
The switch positions for ON or OFF are printed onto the termination
switch. Only the specified switch positions are permitted.
S1 S2 S3 S4 Function
Transmitter Receiver
I I I I Termination is ON
Termination is OFF
Fig. 7-10: Termination switch

Table of Contents