EasyManua.ls Logo

Bosch Rexroth IndraDrive CDB02 - Electrical Data

Bosch Rexroth IndraDrive CDB02
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical data
Single-ended
Data Symbol Unit min. typ. max.
Input voltage
U
ext
V 5 30
Current consumption at U
ext
I
ext
mA 25
25 + 3×I
out
Output voltage "high"
U
Out_High
V
U
ext
- 2V
U
ext
Output voltage "low"
U
Out_Low
V 0 1.5
Output current
I
Out
mA - 40
Overload protection - - Present
Short circuit protection - - Present
Tab. 8-9: Single-ended
RS422
Data Symbol Unit min. typ. max.
Output voltage "high"
U
Out_High
V 2.5 5
Output voltage "low"
U
Out_Low
V 0 0.5
Output current
I
Out
mA - 20
Overload protection - - Present
Short circuit protection - - Present
Tab. 8-10: Outputs, RS422
Data Symbol Unit min. typ. max.
Input voltage "high"
U
In_High
V 2.5 5
Input voltage "low"
U
In_Low
V 0 0.5
Input resistance (difference)
R
In_D
ohm 110 130
Input resistance
R
In
kOhm 150
Overload protection - - Present
Short circuit protection - - Present
Tab. 8-11: Inputs, RS422
DOK-INDRV*-CXX02******-PR03-EN-P Bosch Rexroth AG 101/143
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
Technical data - functions