82 VPV Vane Pump
Through Drive Horsepower Limitations
The VPV pumps can be cooupled with other VPV pumps, Bosch gear pumps or other pumps
with standard SAE or metric mounting patterns. (VPV pumps can be coupled without losing
use of stroke limiter.) VPV combination pumps are rated to carry the load of an additional
pump(s) equal to the maximum load the lead VPV pump can generate (see chart).
EXAMPLES:
VPV 100 @ 3045 psig + VPV 63 @ 3045 psig + VPV 25 @ 3045 psig
88.8 hp ≥ 58.5 hp + 23.3 hp
VPV 116 @ 3045 psig + VPV 16 @ 1500 psig + VPV 16 @ 1500 psig
17.6 hp ≥ 8.7 hp + 8.7 hp
Flow @ 1750 Maximum Pump #1 Maximum Input
RPM Pressure Input Power for other
Pump (gpm) (psig) Horsepower pumps
VPV 16 8.03 3000 17.6 17.6
VPV 25 12.6 3000 25.3 25.3
VPV 32 15.4 3000 30.7 30.7
VPV 45 21.8 3000 43.3 43.3
VPV 63 29.6 3000 58.5 58.5
VPV 80 37.2 3000 74.6 74.6
VPV 100 46.2 3000 88.8 88.8
VPV 130 60.0 3000 117.6 117.6
VPV 164 75.8 3000 156.5 156.5