STANDARD FLUE HORIZONTAL
0100
MAX
686
mm
Ax
1
MIN 250
mm
Ax
1*
0125
MAX 1070
mm
Ax
1
MIN 250
mm
Ax
1*
* Requires cutting
MAXIMUM FLUE HORIZONTAL
0100-
7goo
mm
Ax1+Bx8
0125-
18500
mm
Ax1+Bx18
MAXIMUM FLUE VERTICAL START+ 1 BEND
0 c
0100-
7goo
mm
Ax1+Cx1+Bxg
+
Fx
1
0125-
18500
mm
Ax1+Cx1+Bx1g
+
Fx
1
MAXIMUM FLUE
HORIZONTAL+
1 BEND
bJ) 0
'-----_
'---ll<CI
IP A
B
0 c
0100-
5goo
mm
Ax1
+
Bx7+Cx1
0125-
16500
mm
Ax1
+
Bx17+Cx1
FLUE
OPTIONS 30CDi
CONVENTIONAL
MAXIMUM FLUE VERTICAL
START+
2 BENDS
F 8 d
I
IPA
B
~---~
co
0100-
5goo
mm
Ax1+Cx2+
Bx8
+
Fx
1
0125-
16500
mm
A X 1 + c X 2 + B X
18
+
Fx
1
MAXIMUM FLUE VERTICAL
START+
3 BENDS
F
B
c 0
0100-
3goo
mm
Ax1+Cx3
+Bx7+Fx1
0125-
14500
mm
Ax1+Cx3
+Bx17+Fx1
MAXIMUM FLUE VERTICAL
WITH
2 X 45° BENDS
E
B
D
0100-
7400
mm
(including terminal)
Bx8+Dx2+Ex1
0125-
16500
mm
(including terminal)
Bx17+
Dx2
+Ex1
VERTICAL FLUE WITH
2 X
goo
BENDS
E
B
c 0
0100-5400
mm
(including terminal)
Bx7+
Cx2
+Ex1
0125-
14500
mm
(including terminal)
Bx16+
Cx2
+Ex1
6
720
611
927-08.10
FLUE OPTIONS 30CDi
CONVENTIONAL
•
The
diagrams (opposite) show the compo-
nents used and the maximum flue length for
each configuration of
100
mm
and
125
mm
0 flues.
• Shaded flue components indicate the stan-
dard 100
mm
0 horizontal flue.
• Only straight flue sections can be reduced
in
length and cut.
•
The
flue terminal end can be fitted from the
inside or outside of the building.
Fixing kits
are
supplied with the flue exten-
sion kits.
Horizontal125
mm
0 and Vertical100
mm
and 125
mm
0 flue kits
are
available with
separate instructions. Contact your supplier
or Worcester Bosch.
A c D
QH
iP
0
v
B
EB
F
Q
A - Standard horizontal flue
(1
00
mm
0 shown)
B - Straight flue extension
C -
Flue
bend,
goo
D -
Flue
bends, 45°
E - Vertical terminal (vertical adaptor supplied
with terminal)
F-
Vertical adaptor (used with horizontal
terminal)
Calculating the flue length:
Measure the total flue length required, noting
that the maximum straight flue
length including
the terminal is:
Horizontal
60/100
mm
0:
7goo
mm
Horizontal 80/125
mm
0:
18500
mm
Vertical 60/100
mm
0:
g400
mm
Vertical 80/125
mm
0:
18500
mm
Then reduce the total straight flue length for
each extra flue bend (excluding the turret) by:
2000
mm
for
goo
1000
mm
for 45°
Flue
extension total lengths:
Horizontal
& Vertical 60/100
mm
0:
g5o
mm
Horizontal & Vertical 80/125
mm
0:
1000
mm
Flue
terminal total lengths:
Horizontal
60/100
mm
0:
800
mm
Horizontal 80/125
mm
0:
1200
mm
Vertical60/100
mm
0:
1140
mm
Vertical 80/125
mm
0:
1365
mm
INSTALLATION & SERVICING INSTRUCTIONS
FOR
WORCESTER BOSCH GREENSTAR 30CDI/40CDI Coc,ectlocal
~ORCESTER
6 720
614
556a
(2007/07)
Bosch
Group