INSPECTION AND SERVICE
rDTi51
lQlQj
rn-
CJooo
Dd'
E
H
M
I
I
INSPECTION AND SERVICE
Setting Boiler to Maximum.
A -
On/off
button
B-On/off
and fault indicator
(BLUE)
C - Temperature control
D-
Burner indicator
(GREEN)
E - Reset button
F -
Service button
H-
Not
used
K-
Display
L -
Boost
button
M-
Not
used
~
Press and
HOLD
boost
button (L) for 10
seconds
and set the heating temperature
to
max1mum.
The
boost
button will illuminate continually.
The boiler will stay
in
this mode
for
15
minutes
unless the
boost
button is pressed
again.
2
~
Pull the
cover
off
and
connect
a manome-
ter to the fan pressure test point.
~After
measurement replace
test
point
cover.
Pressure will read negative and
be
greater than:
30CDi-
3.9
mbar
40CDi
-
4.4
mbar
Pressures measured
below
these figures
will indicate that the heat exchanger will
require cleaning.
There is a special
accessory
kit available
specifically
designed
for cleaning the heat
exchanger.
If required order 7 719 001 996.