Installation
Greenstar Utility
ErP -
6 720 821 751 (2018/04)26
5.7 Refitting components
Fig. 35
Align burner combustion head into appliance housing tube flange,
ensure that the burner is level.
Push the burner forward into the flange ensuring that the seal is
properly seated.
Secure with retaining nut.
Tighten retaining nut sufficiently to ensure a good seal.
Connect the burner lead into the control box socket.
Attach air duct [1] and tighten hose clip [2] to secure to the burner
air intake box and the burner air intake [3].
5.8 Electrical
Access to 230V connections:
1. Pull the control knob [D] forwards to remove from control panel [C].
2. Release screws [B] and remove cover panel [C] from control box [A].
3. Release screw [E] from cable clamp [F].
Pull inner clamp part [G] outwards.
Feed sufficient power cable [H] through the cable clamp [F] and
secure grip with screw [E].
Separate wires from cable end and strip to 6mm.
230V connections:
4. Connect SWITCHED LIVE wire (Brown or RED) to terminal L.
Connect NEUTRAL wire (Blue or Black) to terminal N.
Connect EARTH wire (Green/Yellow) to the terminal .
5. Secure the cable to the cable clamp [J].
Route the power cable to the external connection point avoiding any
potentially hot surfaces.
Refit electric control panel cover:
Refit cover panel [C] to control box [A] and secure with screws [B].
Refit control knob [D].
WARNING: Flue gas leakage
The seal between the burner and the mounting flange
must form a gas tight seal to prevent leakage of
potentially dangerous gas from the combustion
chamber.
Unless the burner is level when pushing the burner
into the flange the O-ring may not seat properly
allowing flue gas to escape!
Always check that the O-ring seal is in good condition
before fitting the burner.
Replace the O-ring seal if defective.
6720821683-25.1Wo
A
1
2
3
6720821751-50.1Wo
DANGER: ISOLATE THE 230V ELECTRICITY SUPPLY
Ensure that the electricity supply is safely Isolated
and secured to prevent inadvertent re-connection.
Information on safe isolation can be found in the
Health and Safety Executive guidance HSG85. Using
the test equipment approved to GS38 confirm that
the electricity supply is disconnected.
The mains electrical supply to the appliance and
system wiring centre must be common and through
either a common fused double pole isolator or a
fused three pin plug and unswitched socket.
The isolator shall be sited next to the appliance for
new systems and where practicable, replacement
appliances.
The isolator must have a contact separation of 3mm
minimum between the poles.
Any additional components that are connected to the
appliance with mains electrical supply must not have
a separate supply.
External fuse 5 Amps.
When stripping wires ensure that copper strands do
not fall into the control box.
NOTICE: Any external device connected to the
appliance must take its power supply from the appliance
only and must NOT have a separate supply.
See the following pages of electrical diagrams for details
of different systems.