Appliance information
Greenstar Utility
ErP -
6 720 821 751 (2018/04)6
3 Appliance information
3.1 General information
Standard package
1 - Floor standing oil fired condensing appliance
2 - Literature pack:
Greenstar Utility Installation, Commissioning and Servicing
instruction manual
User Instructions
Guarantee registration card
3 - ErP label
Fig. 1
[A] 1098mm
[B] 795mm
[C] 598mm
3.2 Technical data
A
C
B
6
720821751-03.1Wo
2
1
3
Description Units 32/50 50/70
Central heating
Primary water capacity (total) litres 50 51
Maximum static head metres 30 30
Minimum static head metres 11
Water side resistance (20°C difference) mbar 24 45
Flue
Exit flue gas mass flow kg/hr 76 106
Conventional flue (min. diameter required) mm 130 130
Room sealed flue (diameter) mm 100/
150
100/
150
Pipework connections
Fuel line (compression) mm 10 10
CH flow inch BSP
CH return mm 28 28
CH vent inch BSP
Condensate (polypropylene) mm 21.5 21.5
Electrical
Electrical power supply voltage AC. . .V 230 230
Frequency Hz 50 50
Thermostats
Appliance flow temperature range (cut out) °C 50/80 50/80
CH control thermostat differential °C 55
Appliance high limit thermostat set point
(+ 0 / - 6°C)
°C 95 95
Appliance manual reset overheat
thermostat (cut out)
°C 105 105
Flue manual reset overheat thermostat
(+ 0 / - 6°C)
°C 110 110
General data
Maximum hearth temperature °C < 85 < 85
SEDBUK 2005 (Band A) % 93.0 92.5
SEDBUK (2009) % 90.7 90.5
Appliance protection rating IP 20 20
Weight (excluding packaging) kg 215 220