35
19 - TECHNICAL CHARACTERISTICS
Unit for domestic use.
• Independently installed electronic device.
• LCD display.
• Power supply: 3 alkaline LR03 penlight AAA
1.5V batteries.
• Autonomy: over 1 year.
• Battery low warning.
• Time available for battery replacement: approxi-
mately 2 minutes.
• Relay: max. voltage 250 V, max. current 5A with
resistive load (2A with inductive load).
Type of action: 1B-U.
• Range of adjustment in heating mode: from 6°C
to 24°C
• Range of adjustment in cooling mode: from
18°C to 31°C
• Three operating modes: MANUAL, AUTOMAT-
IC, SYSTEM BYPASS
• Selectable programmes HEATING, COOLING
• Manual mode timer or system bypass in hours or
days up to a maximum of 99.
• Room temperature measuring interval: 15 s.
• Thermal differential: adjustable from 0.1°C to
0.9°C
• Reading resolution: 0.1°C.
• Displayed reading range: from 0°C to +40°C
• Precision: ≤ ±0.3°C.
• Class A software.
• Degree of pollution: 2.
• Impulse voltage: 4 KV.
• Maximum control unit temperature: 40°C.
• Operating temperature: from 0°C to +40°C.
• Protection rating: IP30.
• Dimensions: 139 x 94 x 26mm.