AUTO CUTTER OPERATORS MANUAL 13 Edition 04/10
Maintenance
Changing the Blades
6-2 Changing the Blades
WARNING
Disconnect the printer from the electrical outlet.
1. Remove the cutter from the printer.
2. Remove the cover sheets (see "6-1: Cleaning" on page 10).
3. Turn the axle [3] of the circular blade [2] with a screwdriver for slotted head
screws (slot width 7 mm) so that the inscription [1] of the blade points
downward. In this position the set screw [4] on the gear wheel can be
achieved from the rear of the cutter.
4. Loosen the set screw [4] a few turns.
Note: Save the washers (A, B, C) for the circular blade [2] and the lineal blade [12]
when dismounting the cutter.
CAUTION!
The springs [6, 15] are tense. Always hold lineal blade [12] in its position tightly
and push its axle slightly to the mounting plate [9] of the cutter.
5. Loosen the screws [8] and remove the bearing plate [15]. The spring [13]
becomes slack.
6. Remove spring [13] from the lineal blade.
7. Pull the circular blade [2] out of the bearing [5]. The spring [6] at the lineal
blade becomes slack.
Note: If the lineal blade should not be changed, skip to step 11.
321