Startup
5-5
Digital Compact
2002 BRANSON Ultrasonics Digital Compact Version22.08.2002
the open end wrenches.
Horns having a rectangular cross-section may be carefully secured
in a vice equipped with jaws of soft metal (brass or aluminium).
CAUTION!
NEVER attempt to assemble or disassemble the acoustic stack by
holding the booster or converter in a vice
(see Fig. 5-2).
In case you have to assemble or disassemble acoustic stacks
regularly, a special installation fixture is available from BRANSON
Ultrasonics.
Fig. 5-2 Securing the acoustic stack
For disassembly of the acoustic stack proceed in reverse order.
!
Correct! Wrong!