100-412-197 REV. 07 65
* If the input signals are not within their valid range, or if left unconnected, the power supply will use 50%
amplitude and zero frequency offset, respectively.
22
STD-Confirm Preset
Change
Output
Digital
+24 V indicates a load new preset
request has occurred and the preset
was successfully recalled.
23 ACT-Trigger Switch Input Digital
+24 V must be present for
ultrasonics to be enabled.
24 Power Out
Output
Analog
0 V to + 10 V (0% to 100%)
25 Amplitude Out
Output
Analog
0 V to + 10 V (0% to 100%)
26 Analog Signal Return
Analog Signal
Return
Return for pins 17, 18, 24, and 25
Table 5.15 Default Branson User I/O Connector PIN Assignments, V6.0
Pin Function I/O Type Values