â– Error Code D100
Modem PCB initialization failed.
Error Code D200
SDAA communication failure
â– Error Code D800
Touch panel initialization failed.
â– Error Code E200
Wired LAN MAC address not registered.
â– Error Code E300
Wireless LAN connection error
â– Error Code E600
Main PCB EEPROM write error
Step Cause Solution
1 Modem PCB harness
connection failure
Reconnect the modem PCB harness.
2 Modem PCB defective Replace the modem PCB.
3 Main PCB defective Replace the main PCB.
Step Cause Solution
1 Touch panel defective Replace the touch panel.
2 Main PCB defective Replace the main PCB.
Step Cause Solution
1 Main PCB defective Replace the main PCB.
Step Cause Solution
1 Wireless LAN PCB connection
failure
Reconnect the wireless LAN PCB.
2 Wireless LAN PCB defective Replace the wireless LAN PCB.
3 Main PCB defective Replace the main PCB.
Step Cause Solution
1 Main PCB defective Replace the main PCB.