29
 &"  #"! !$! #
(98/12/10)
W3 set
W2 set in pos. B
W7 set in pos. B and C
W8, W9 nothing to set, test signals
3. 8. 3. Configurations of the introduced layout
CCU configuration of Serial Interfaces:
CU10
UNIX
Special File
/dev/tty00
/dev/
tty01,...,05
/dev/
tty06,...,07
/dev/tty08 /dev/tty09 /dev/tty10 /dev/tty20
Function (Console) RS232 RS485
CCU
Connector
ST7 ST8 ST9 ST9 ST2 ST2
AQX Ext. U.
Connector
N/A
ST2,...,ST
6
ST7,...,ST
8
ST9 ST10 N/A N/A
Pin out of the X3 connector at the AQS backplane :
Signal Signal
2
TxD-_1
1
TxD+_1
4
GND
3
GND
6
RxD-_1
5
RxD+_1
8
SGU Stop
7
WUP_1
10
+12V
9
+12V
12
+12V
11
+12V
14 13
WUP_2
16
RxD-_2
15
RxD+_2
18
GND
17
GND
20
TxD-_2
19
TxD+_2
Note: UNIX Special Files for RS485 interfaces
/dev/tty10: TxD–/+ 1, RxD–/+ 1, WUP 1
/dev/tty20: TxD–/+ 2, RxD–/+ 2, WUP 2
CCU/10 DRAM configuration:
Select Jumper W5
SEL0 1 o––––o 2 SHORT
SEL1 3 o o 4 OPEN