Quick Reference Guide QRG
Step 3: Set position for software limit switch 2
7. Move guiding device to the desired position for software limit
switch 2 (towards sensor 2) using the arrow keys.
or
The position indicator for software limit switch 2
shows the actual value supplied by the position feed
back of the actuator.
Range of values: -2048 … +2047.
8. Press key Sensor 2.
The position for software limit switch 2 is stored.
The symbol “sensor 2“ is represented inversely.
Step 4: Set servo-center position
9. Move actuator to the desired center position for the guiding
device using the arrow keys.
or
The position indicator for the servo-center position
shows the actual value supplied by the position feed
back of the actuator.
Range of values: -2048 … +2047.
10. Press key Servo-center.
The actual position is stored as servo-center position.
The symbol “servo-center“ is represented inversely.
Step 5: Exiting the settings
11. Press key ENTER.
The setup menu will be closed.
All modified parameter values are stored.
Quick Reference Guide EDV no.: MD.341.01.01
ekr 500 Plus with CLS Pro 600 Issue Date: 31.03.2009 Page: 10/18