Commissioning
3
ekr 500 digital Unit Touch – CANopen User Gateway 21/67
3. Set the DIL switches S5.7 and S5.8 on the processor board of
the controller according to the desired baud rate (see table).
4. Close the controller’s housing cover.
5. Switch on the power supply of the controller again.
Changes to the DIL switch settings will become active
only after a restart of the controller.
3.5 Selecting the Communication Protocol
During commissioning of the CANopen user gateway, you have to
select the communication protocol that is to be used to exchange
data with the ekr 500 digital Unit Touch web guiding controller.
The protocol is selected at the controller using the userprotocol
xxxx parameter of the public parameter list 0.
For standard applications, we recommend the use of the protocol
3100.
Procedure
›› The controller is in the Manual operating mode.
1. Press the SETUP key.
The controller changes to setup mode.
The first page of the setup menu appears in the display.
2. Activate the System components service display by tapping the
adjoining button.
A list including all system components connected is displayed.
3. Tap the ekr500d entry in the list of the system components.
The Switch positions service display for the controller appears
in the display.
4. Press the Sensor3 key.