Manual EVOTOUCH v.5 59 / 104
1.3.2 Common Technical specifications to all families of
BSsalt/EVO/EVOTOUCH equipment
- Adjustment of chlorine production by switched mode power supply
- Power supply performance >90%
- Automatic switch-off owing to lack of water flow
- Automatic switch-off owing to the accumulation of gas in the cell, with
automatic restart once the water flow is restored.
- Automatic voltage adjustment depending on the concentration of salt and
the temperature, keeping continuous chlorine production.
- Automatic cleaning cycle of electrodes.
- Automatic restart if power supply failure is detected.
1.4- Recommendations and safety precautions
- The equipment must always be installed by qualified staff.
- Disconnect the equipment from the mains power supply before starting
any assembly or maintenance operation.
- Make sure that the electrical installation has all compulsory
protection elements (circuit breaker and differential switch)
working in perfect conditions.
- It is important to ensure that the supply cables of the
electrolysis cell are tightly connected, otherwise the
equipment could overheat and break down.
- Ensure that the heatsink fins (at the rear of the equipment)
are not blocked and there is a good air flow through them.
- All the BSV equipment incorporate protection systems against short
circuits in the cell, absence of water detection and other safety systems,
it will shows a visual and and acoustic alarm if any anomaly performance
is detected. Although, for optimum results, you should ensure the correct
hydraulic operation of your swimming pool.
- Equipment housing has IP65 protection. However, it is highly
recommended not to install the equipment directly exposed to sunlight.
- Corrosive environments may reduce the lifespan of the equipment. Do
not leave open containers with acids near the equipment.