Manual EVOTOUCH v.5 97 / 104
4.2.1- EVOLINK Warnings
Life cycle of cell is expired.
Clean cell as is explained below
ORP probe is not
connected.
Lack of salt in the water.
Add salt to the swimming pool.
Incrustations or objects in
the electrolysis cell causing
lack of current.
The electrolysis cell is worn.
Replace the electrolysis cell with
a new one.
Excess salt in the water.
No action required if excess is
not very significant.
Incrustations or objects in
the electrolysis cell causing
excess current.
The chlorinator is in the
self-cleaning process. The
process takes 5 minutes
In the following cases, the chlorinator shuts down and the alarm and
acoustic alarm
LED is activated (automatic reset once the fault is solved):
*Except pH Alarm
Excess gas in the
electrolysis cell. It may
have occurred because the
pump has shutdown. The
gas is hydrogen gas which
is highly flammable.
The piping should be drained to
eliminate gas or accumulated
water. Check the pump.
Sensor cable of the cell is
incorrectly connected or
broken.
Check the sensor cable (white
cable)
ORP probe is dirty, worm
or not connected
Check ORP probe conditions, use
pattern liquid