Electrical systems – 5000 LPE 240
Error codes
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497
© BT Europe AB Service Guide LWE180, LWE200, LPE200, LPE240 10- 23
Code E159
Description Transgression error.
Possible error
cause
CAN bus problem.
Action 1. Check 119 and 120 cables and the connec-
tions on the travel regulator.
2. Replace travel regulator.
3. Replace the electronic card
Code E160
Description Error in safety reversing function
Possible error
cause
Error in important sensor part.
Action 1. Replace the electronic card
Code E200
Description Open field.
Possible error
cause
Shunt field’s circuit open.
Action 1. Check the field winding connections E1 and
E2. Unfortunately it is not possible to measure
ohms for the field winding using a standard
universal instrument, since the winding has a
value as low as 0.3 ohm.
2. Check cables 4 and 5 and outputs S1 and S2
3. Replace travel regulator