9- 28 Service Guide LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Electrical System – 5000 LWE 180/200 LPE 200
Error codes
T-code Valid from serial number Date Order number
660, 661, 662, 497 723984- 2005-05-11 225553-040
Code E159
Description Transgression error.
Possible error
cause
CAN bus problem.
Action 1. Check 119 and 120 cables and the connec-
tions on the travel regulator.
2. Replace travel regulator.
3. Replace the electronic card
Code E160
Description Error in safety reversing function
Possible error
cause
Error in important sensor part.
Action 1. Replace the electronic card
Code E200
Description Open field.
Possible error
cause
Shunt field’s circuit open.
Action 1. Check the field winding connections E1 and
E2. Unfortunately it is not possible to measure
ohms for the field winding using a standard
universal instrument, since the winding has a
value as low as 0.3 ohm.
2. Check cables 4 and 5 and outputs S1 and S2
3. Replace travel regulator