Electrical systems – 5000 LPE 240
Parameters
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497
© BT Europe AB Service Guide LWE180, LWE200, LPE200, LPE240 10- 29
Parameter 17 - Configurable option #2
See “Option parameters” on page 29, Servicemanual
Parameter 18 - Configurable option #3
See “Option parameters” on page 29, Servicemanual
Parameter 19 - Configurable option #4
See “Option parameters” on page 29, Servicemanual
Option parameters
WARNING !
Do not try to change these parameter unless you have specific knowl-
edge of the truck options or truck modifications. This service manual
only covers the truck’s standard equipment. Specially modified
trucks may require you to have access to particular service informa
-
tion. Incorrect adjustment of option parameters may result in incor-
rect function.
General
Parameters #15 to #19 have been reserved in the truck control system
for extra options and/or specific product modifications. These parame
-
ters are normally configured by the manufacturer on modification or
customisation of the truck. It is recommended that the parameter set
-
tings be loaded up from the truck when carrying out any modification. If,
for example, the main logic card [A2] must be replaced, the original
parameter settings can then be simply transferred to the new card,
which ensures that all the special options function correctly.
Parameter #15 Non-configurable options
Up to 16 so-called sub-parameters are stored under parameter #15.
Their status is either ON or OFF and they do not require any other
adjustments. They are therefore called non-configurable options.