Electrical System – 5000 LWE 180/200 LPE 200
Parameters
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497 
© BT Europe AB Service Guide  LWE180, LWE200, LPE200, LPE240 9-  35
The parameter symbol flashes. .
• Enter the sub-parameter value by repeatedly operating the speed 
control L1 in either direction. See 
Table 1: for more information.
• Press the S18 horn button once to confirm the new setting.
The parameter symbol is lit (i.e. stops flashing).
• Switch off the truck by pressing    on the keypad.
The non-configurable option is now activated.
• Check that the function works correctly before the truck is put back 
in operation.
P
Parameter #16 to 19 configurable optional functions
Parameter no. #16, #17, #18 & #19 can be adjusted to activate up to a 
maximum of 4 pre-programmed functions and configure these to suit 
optional equipment or customisation of the truck. See 
“Table 2:List of 
configurable optional functions” on page 37. These are thus called the 
configurable optional functions.
• Each parameter can be programmed to cover a specific optional 
function. 
• Each optional function can have up to 4 independent variables asso-
ciated with it. 
• Each independent variable has a value you can change to configure 
the function.
Table 1: Parameter #15 Non-configurable option
Sub-parameter no.
Function name Value Note!
Function ON
Function OFF
Basic setting
1 "Turtle" function 1 0 0
2 to 9 For future use - - -