Electrical System – 5000 LWE 180/200 LPE 200
Parameters
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497
© BT Europe AB Service Guide LWE180, LWE200, LPE200, LPE240 9- 35
The parameter symbol flashes. .
Enter the sub-parameter value by repeatedly operating the speed
control L1 in either direction. See
Table 1: for more information.
Press the S18 horn button once to confirm the new setting.
The parameter symbol is lit (i.e. stops flashing).
Switch off the truck by pressing on the keypad.
The non-configurable option is now activated.
Check that the function works correctly before the truck is put back
in operation.
P
Parameter #16 to 19 configurable optional functions
Parameter no. #16, #17, #18 & #19 can be adjusted to activate up to a
maximum of 4 pre-programmed functions and configure these to suit
optional equipment or customisation of the truck. See
“Table 2:List of
configurable optional functions” on page 37. These are thus called the
configurable optional functions.
Each parameter can be programmed to cover a specific optional
function.
Each optional function can have up to 4 independent variables asso-
ciated with it.
Each independent variable has a value you can change to configure
the function.
Table 1: Parameter #15 Non-configurable option
Sub-parameter no.
Function name Value Note!
Function ON
Function OFF
Basic setting
1 "Turtle" function 1 0 0
2 to 9 For future use - - -