Electrical System – 5000 LWE 180/200 LPE 200
Parameters
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497 
© BT Europe AB Service Guide  LWE180, LWE200, LPE200, LPE240 9-  33
9.6.4 Parameter description
Parameter 10
NOTE!
The functionality of parameter #10 is set aside if the value of parame-
ter #39 is set to 5,6,7 or 8. The PIN codes are managed using the so-
called expanded keypad. See section 
Expanded keypad - General on 
page 45 for more detailed information.
Ten drivers can have their own PIN code to gain access to the truck. 
Each driver can set all driver parameters individually.
On delivery the PIN code is set to 1 and this only applies for driver no. 1.
Code 0 is not accepted as a solitary code.
When you wish to start the truck enter your code and press the green 
button numbered 1.
When you want to switch off the truck, press the red button numbered 0.
When the CAN key is connected, you can start the truck by simply 
pressing the green button numbered 1.  Switch off by pressing the red 
button numbered 0.
Parameter 14
Specifies the speed you will have when you reach the first speed sensor.
Parameter 15 - Non-configurable option
See “Option parameters” on page 34, Servicemanual
Parameter 16 - Configurable option #1
See “Option parameters” on page 34, Servicemanual
Parameter 17 - Configurable option #2
See “Option parameters” on page 34, Servicemanual
22 Inductive 
sensor
0 1 1 1 0: Mechanical switch
1: Inductive sensor
25 Service inter-
val
1h 0 2000 50 100 Option for setting service timer
28 Lift button 
selection
1 3 1 1 Button selection
39 Password 1 12 1 1 States which level of authoriza-
tion the driver has for the 
parameters.
Odd values specify open driver 
parameters, even values spec
-
ify that driver parameters must 
be opened using the CAN key
Parameter Description Unit Min. Max. Step Std. Description