9- 30 Service Guide LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Electrical System – 5000 LWE 180/200 LPE 200
Parameters
T-code Valid from serial number Date Order number
660, 661, 662, 497 723984- 2005-05-11 225553-040
9.6 Parameters
Press and hold S18 while turning S17 to “ON” position.
Press and hold S18 until P = parameters is displayed.
You have now selected P = parameters and the symbol “C” is lit as
an indication of what is now shown in the display.
Press L1 up or down and scroll to the parameter you want to change
or view.
Press S18 once to access the parameter.
Press L1 up or down to specify the parameter value.
Press S18 once to confirm the change.
Turn S17 to the off position.
You have now changed the parameter and the new setting will come
into force the next time you start the machine.
NOTE:
Truck handling
When you change specific truck parameters, the truck’s driving char-
acteristics are also changed.
Do not change any parameters unless you really know what you are
doing.
9.6.1 Operator parameters
Parameter Description Unit Min. Max. Step Std. Description
01 Speed, Turtle
button
% 40 100 5 100 Speed, Turtle button
10: slow speed
100: maximum speed.
02 Max. speed % 40 100 5 100 Max. speed
10: slow speed
100: maximum speed
03 Acceleration 10 100 5 50 10: slow acceleration
100: maximum accelera-
tion
04 Braking in neu-
tral mode
5 100 5 50 Specifies motor braking
once the lever is put into
neutral.
5: weak braking power
100: maximum breaking
power
05 Logout 1min 0 20 1 20 The time it takes for the
truck to switch off when
the keypad is used. The
time counts down from
the moment the last
power-consuming unit is
used.
Value = 0 gives 4 hours.
In steps of 1