Electrical System – 5000 LWE 180/200 LPE 200
Parameters
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497
© BT Europe AB Service Guide LWE180, LWE200, LPE200, LPE240 9- 31
9.6.2 Parameter description
Parameter 1
The speed of use of the turtle button can be adjusted.
Parameter 2
The maximum speed can be adjusted.
Parameter 3
The lower the parameter value, the longer it takes for the truck to
achieve maximum speed.
Parameter 4
Specifies the motor braking power when the lever (L1) is put into neu-
tral. The lower the parameter value, the longer the braking time.
Parameter 5
The time it takes for the truck to switch off when the keypad is used.
The time counts down from the moment the last power-consuming unit
is used.
Value = 0 gives 4 hours.