EasyManua.ls Logo

BT LWE200 - Recommendation on Parameter Setting for Freely; Ventilated Batteries

BT LWE200
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical System – 5000 LWE 180/200 LPE 200
Parameters
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497
© BT Europe AB Service Guide LWE180, LWE200, LPE200, LPE240 9- 41
Recommendation on parameter setting for freely
ventilated batteries
WARNING !
The service life of the battery will be reduced if the value of parameter
21 is set at too high a value. The standard setting of parameter 21 is
set for normal truck handling. Other applications may require a differ
-
ent setting of parameter 21. Check that the parameter setting is the
correct one using the instructions below.
Parameter 21 Battery size
LWE180, LWE200,
LPE200-6
Battery size
LPE200-8
Less dis-
charge
Greater dis-
charge
1
2
3
4
5 260Ah - 320Ah
Standard value
6 190Ah - 250Ah
7 120Ah - 180Ah 260Ah - 320Ah
Standard value
8 190Ah - 250Ah
9 120Ah - 180Ah
10
11
12
13
14
15
16
17
18
19
20

Table of Contents