Preventive maintenance – P2 LWE 180/200 LPE 200
Maintenance schedule
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497
© BT Europe AB Service Guide LWE180, LWE200, LPE200, LPE240 4- 1
4- Preventive maintenance – P2
LWE 180/200 LPE 200
4.1 Maintenance schedule
I: Inspect, rectify and change if necessary. T: Tighten. C: Clean. L: Lubricate.
M: Control measurement, rectify if necessary
Pos.
No.
Work to carry out
Interval in hours 5 20 80 500 1000 3000
Interval in days/weeks/months 1d 1w 1m 6m 12m 36m
0000 Chassis
0000.1 Check all links and locking pins l
0000.2 Check wear on cover/battery locking l
0000.3 Check of cracking and damage l
0000.4 Check the cover locks I
0000.5 Check finger guard I
0000.6 Check signs and stickers I
0000.7 Press grease into grease nipples
I/L
6
0380 Fork carriage
0380.1 Check for crack formation and damage l
0380.2 Check clearance in bushes and links I
0380.3 Press grease into grease nipples (Option)
I/L
6
0380.4 Check the lift limit switch l
0560 Platform and mountings
0560.1 Check for any cracks or damage l
0560.2 Check gas damper and cup springs l
1700. Drive motor
1700.1 Check clearance in connections
I/T
1
I/T
1700.2 Check the carbon brushes in the drive motor M
1700.3 Clean the drive motor C
1700.4 Re-tighten the attachment bolts
T
2
1700.5 Check for abnormal noise in bearing l