Controls and instruments
© BT Industries AB 222714-040
29
Display and programming
It is possible to look in the machine-specific register, but not to
re-programme. However, you can re-programme the operator-
specific parameters. The parameters can be found in the table
“Parameters” on page 30. For further information regarding
parameters and warning and error codes, see the Service Man-
ual (SM).
Display
Follow the instructions below to look into the operator and
machine-specific register:
• Press the horn button while at the same time pressing “I”.
The display will now show the functions:
- Running time and time remaining until next service (H)
- Error codes (E)
- Parameters (P)
- Hardware and software numbers (Pn)
• Release the horn button at the required display.
• Step between the different functions above by turning the
speed control.
Programming
To re-programme the operator-specific parameters (if the
change is permitted), carry out the following:
NOTE.
Truck handling.
The handling characteristics of the truck will change if you
change any of the truck specific parameters. Do not change
any parameters without possessing the necessary know-how.
Truck with keyboard
• Enter the number of the driver whose parameters are to be
changed using the keyboard.
• Press “I” on the keyboard while at the same time pressing the
horn button, or just press the horn button.
• Release the horn button when the display shows “P”.
The parameter symbol on the display lights.
• To locate the required parameter turn the speed control until
the display shows the correct parameter number.
• Press the horn button once to change the value.
The parameter symbol on the display starts flashing.
• Change the value by turning the speed control.