T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
24- 32 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Warning Codes without registration
Brakes, R2
1. Check that the brake pedal has not stuck in the actuated posi-
tion.
2. Check that R2 is located in its bracket.
Check that there is no play or oxidisation on the connector
pins on terminal X36. The voltage on input 502 should be 1.7 +/
- 0.2 VDC when R2 is correctly mechanically adjusted.
3. For calibration of the brake control, see the section “Parame-
ter setting” in this manual.
(Deactuated position).
4. If the voltage on input 502 is correct and calibration does not
rectify the problem, then replace the A5 electronic card.
Code 17
Description Voltage from the brake pedal potentiometer R2 is
outside of the calibrated value at start up
(+/-0.2 V).
Error mode Start up error
Error cause 1. Activated brake pedal at start up
2. Faulty potentiometer/bracket/wiring
3. Calibration error.
4. Defective electronic card A5
Comments Manoeuvre to neutral position