Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 24- 33
Electronic card – 5710
Warning Codes without registration
1. See section “Parameter Settings” in this manual.
Code 18
Description Battery on the electronic card has reached the lowest
voltage
Error mode Internal clock stops
Error cause 1.Battery voltage too low
Comments
Code 19
Description Previously programmed values missing
Error mode Standard values have been loaded
Error cause Displaced A5 electronic card
1. Program A5 card
Comments