T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
24- 56 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Warning codes with registration
Hydraulic valve Y12 operates the retraction of the fork carriage.
1. Check that the switch S133 is open.
2. Disconnect the cable 90 from output 702.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that the cable 90 is intact between terminal 702 and the
terminals in X17 via X14.
- Measure the coil on Y12 between the red and black cables in X17
with an ohmmeter. Resistance approx. 90 ohm.
- Check that cable 40 is intact from X17 via X14 to the battery neg-
ative.
3. If the fault remains, replace A5.
Code 59
Description Output 702 short circuit/breakage
Error mode General error
Error cause 1. Emergency switch for Y12 activated
2. Faulty wiring/valve Y12
3. Defective electronic card A5
Comments