Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 24- 57
Electronic card – 5710
Warning codes with registration
Hydraulic valve Y13 operates the extension of the fork carriage.
1. Disconnect the cable 91 from output 703.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that the cable 91 is intact between terminal 703 and the
terminals in X17 via X14.
- Measure the coil on Y13 between the blue and black cables in
X17 with an ohmmeter. Resistance approx. 90 ohm.
- Check that cable 40 is intact from X17 via X14 to the battery neg-
ative.
2. If the fault remains, replace A5.
Code 60
Description Output 703 short circuit/breakage
Error mode General error
Error cause 1. Faulty wiring/valve Y13
2. Defective electronic card A5
Comments