T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
10- 6 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electric pump motor –1710
Installation instructions for external temperature sensor
A fully functional temperature sensor mounted inside the motor should
have a resistance value of approx. 550 ohm at a temperature of 20
degrees.
The temperature sensor mounted on the outside has a resistance value
of approx. 670 ohm at a temperature of 20 degrees.
The temperature sensor can be mounted to the right or left of the ter-
minal block, depending on which side is easiest to access.
Scrape the surface clean where the new temperature sensor is to be
mounted.
Place the temperature sensor as shown in the picture.
Apply metallic lacquer over the sensor. Ensure that the entire sensor
is covered by the metallic lacquer.