Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 10- 7
Electric pump motor –1710
Installation instructions for external temperature sensor
• Fasten the metallic lacquer and the sensor with masking tape and
allow it to harden.
• Remove the masking tape. The temperature sensor should now be
fixed in place and covered entirely by metallic lacquer.
• Remove the ferrite block from the old sensor and mount it on the ca-
ble to the new sensor.
• Remove the contact from the broken sensor, which is attached to
the motor.
• Place the new sensor contact in the old bracket and connect it to the
cables.
• Fasten the old contact and its cables using a cable tie so it cannot
damage anything.