Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-09-09
© BT Europe AB Service Manual REFLEX RR B,E RR B,E CC 5- 13
Preventive maintenance – P2
Maintenance Schedule
5000 Electrical Panel
5000.1 Clean and check the mountings X
5000.2 Tighten cable connections X
5000.3 Check the emergency driving functions X
5000.4 Check error code log and operation
times
U X
5190.1 Check contactor points X
5190.2 Check movement in the contactor X
5280.1 Check electrical limiting functions X
5110 Battery
5110.1 Check electrolyte levels (10-15 mm over
cell plates)
U X
5110.2 Check connections on the battery, truck
and charger
U X
5110.3 Check the cell and pole guards U X
5110.4 Check fluid density U X
5110.5 Check temperature X
5110.6 Remove overflow fluid from the battery
trough
X
5110.7 Check for wear to the locking catch U X
6000 Hydraulic system
6110.1 Check the tank, mounting and leakage X
6110.2 Check oil levels X
6110.3 Clean or replace the oil B
6120.1 Check the hoses, pipes and couplings U X
6120.2 Check for wear to hoses on the mast and
reach carriage
X
6130.1 Change air and oil filters X
6170.1 Check overflow pressure X
6600 Cylinders
6600.1 Check for leakage U X
Table 5: Maintenance schedule RR B/E 2-8 CC
Pos.
no.
Work to carry out
Interval in hours 5 20 250 500 1000 3000
Interval in days/weeks/months 1 d 1
wk
3 m 6 m 12 m 36 m