7 747 006 21708/2006 GB For the user
Please read carefully before use.
Operating instructions
RC20 room controller

Other manuals for Buderus RC20

Questions and Answers

  • L
    Laura ColeJul 26, 2025
    Why is my Buderus RC20 DHW remaining cold?
    • B
      Brittany RobertsonJul 26, 2025
      If the DHW remains cold, it might be due to several reasons. There could be a constant drawing of water or a system leak, in which case, fix the leak if necessary. The sensor might be incorrectly connected or mounted, the sensor cable could be broken or short-circuited, or the sensor itself might be faulty; check the sensor connection and cable, ensure the sensor is correctly mounted on the storage cylinder, and compare the resistance value with the sensor curve. Alternatively, the charge pump might be connected incorrectly or is faulty, so check the operation of the charge pump.
  • J
    Jonathan LongJul 30, 2025
    What to do if there is no communication with UBA 1/ UBA 3/MC10 on my Buderus RC20 Thermostat?
    • K
      Keith NewmanJul 30, 2025
      If there is no communication with UBA 1/ UBA 3/MC10, the EMS bus system might be overloaded. Try resetting the system by switching the heating system off and then on again.
  • B
    Brad MezaAug 4, 2025
    How to fix no communication with RC30/ RC35 on Buderus RC20?
    • K
      Katelyn RileyAug 4, 2025
      If there is no communication with RC30/ RC35, it might be because the RC20 address is incorrect; check the address (parameter P1) in RC20. Alternatively, the RC30/RC35 might not be present or not connected correctly; check the connection to RC30/ RC35.
  • A
    Alexis JohnsonAug 8, 2025
    What to do if there is an address conflict on my Buderus Thermostat?
    • C
      Christine CalhounAug 8, 2025
      If there is an address conflict, it could be because the RC20 is logged in the system as the sole programming unit (master) with RC30/RC35 also as master. To resolve this, change the address (parameter P1) in the RC20 or remove RC30/RC35 from the EMS.
  • K
    Kevin HawkinsAug 12, 2025
    How to troubleshoot a faulty DHW sensor on a Buderus RC20 Thermostat?
    • M
      Melissa FieldsAug 12, 2025
      If the DHW sensor is faulty, it might be due to incorrect connection or mounting, a broken or short-circuited sensor cable, or the sensor itself being faulty. Check the sensor connection and cable, ensure the sensor is correctly mounted on the storage cylinder, and compare the resistance value with the sensor curve.
  • D
    Debbie JimenezAug 16, 2025
    What causes no communication with BC10 on my Buderus RC20 Thermostat?
    • A
      Andrea BensonAug 16, 2025
      If there is no communication with BC10, it might be due to a contact problem on the BC10 or the BC10 being faulty. Check the BC10 connection and replace the BC10 if necessary.
  • R
    Robert ParksAug 21, 2025
    How to resolve address conflict with RC20 remote control unit on Buderus Thermostat?
    • D
      Douglas OconnellAug 21, 2025
      If there is an address conflict with the RC20 remote control unit, the RC20 address might be incorrectly allocated on the RC30/ RC35 or not installed on the RC30/RC35. Check the 'remote control' parameter on the RC30/ RC35 for this heating circuit.

Summary

Safe Handling of the RC20

Correct Use of the RC20

Specifies the intended use of the RC20 controller with Buderus heating systems.

Important Safety Notes

Provides important user notes and emergency isolation instructions for the heating system.

The Functions of the RC20

Direct Room Temperature Adjustment

Explains how to adjust the room temperature using the rotary selector.

Setting the Room Temperature

Temporary Room Temperature Settings

Describes how to make a temporary adjustment to the room temperature setting.

Heating Domestic Hot Water

Setting Domestic Hot Water Temperature

Guides on how to check and adjust the domestic hot water temperature, including safety warnings.

Setting Day and Time

Configuring Time and Day Settings

Step-by-step instructions for setting the correct time and day on the RC20 controller.

What is a Heating Program?

Heating Program Selection

Tips on Energy-Efficient Heating

Troubleshooting

Frequently Asked Questions

Addresses common questions about room temperature readings and deviations from set points.

Understanding Fault Displays

Details various fault codes and their causes and remedies as shown on the display.

Fault and Special Message Codes

Lists specific fault codes (A01, A11, Hxx) and their associated causes and remedies.

Resetting Faults (Reset)

System Fault Reset Procedure

Explains how to reset faults using the "Reset" button and addresses system damage from frost.

Buderus RC20 Specifications

General IconGeneral
BrandBuderus
ModelRC20
CategoryThermostat
LanguageEnglish