Buderus RC35 - User Manual

Buderus RC35
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
For users
Read carefully before
use.
Operating instructions
Room controller
Logamatic EMS
6 720 618 477-00.1RS
RC35 programming unit
6 720 642 272 (10/2009) GB

Table of Contents

Other manuals for Buderus RC35

Questions and Answers

  • T
    Tara ForbesSep 23, 2025
    What does 'No plant error' mean on my Buderus Control Unit?
    • C
      Cheyenne PhamSep 23, 2025
      If your Buderus Control Unit displays 'No plant error', it can indicate that maintenance is required, such as a service interval that has expired. See boiler documentation.
  • L
    loganjustinAug 23, 2025
    Why was the thermal disinfection unsuccessful on my Buderus Control Unit?
    • C
      christopher69Aug 23, 2025
      If thermal disinfection was unsuccessful on your Buderus Control Unit, it might be because the water draw was too great during the disinfection period. Select a time for thermal disinfection when there is no other demand for heat.
  • J
    Joseph RoseAug 25, 2025
    What to do if my Buderus Control Unit DHW stays cold?
    • M
      melissa15Aug 26, 2025
      If the DHW (domestic hot water) stays cold, it may be due to a constant drawing of water or a system leak. To resolve this, fix any leaks in your system.
  • E
    Elizabeth ArnoldAug 27, 2025
    What to do if the Buderus Control Unit shows a low battery for wireless operating unit HCx?
    • T
      thomas61Aug 27, 2025
      If your Buderus Control Unit displays a low battery warning for the wireless operating unit HCx, the battery in the RC20RF for HCx is low. Replace the batteries to resolve this issue.
  • J
    Jessica MorseAug 27, 2025
    Why is my Buderus Control Unit not communicating with RC35?
    • T
      Teresa ClarkAug 27, 2025
      If there is no communication between your Buderus Control Unit and the RC35, it could be due to a couple of reasons. First, the RC20/RF may have an incorrect address, so check the address (parameter P1) in RC20/RF. Second, the RC35 might not be installed or correctly connected, so check the RC35 connection.
  • J
    Jerry GillSep 17, 2025
    What does 'Frost prot. selected but no rem.contr. HCx' mean on my Buderus Control Unit?
    • M
      martinmelanieSep 17, 2025
      If your Buderus Control Unit shows 'Frost prot. selected but no rem.contr. HCx', it means that no programming unit / remote control unit is assigned, even though frost protection is set to room temperature. Check the operating unit parameter and change frost protection to outside temperature if necessary.
  • K
    Kayla NobleSep 14, 2025
    What causes no communication with operating unit HCx on my Buderus Control Unit?
    • P
      Paul KingSep 14, 2025
      If there is no communication with operating unit HCx on your Buderus Control Unit, it could be because the RC20 has an incorrect address, is incorrectly wired, or is faulty, or the heating circuit has not been registered on the RFM20. Check the address in the RC20, check the function and connection of the remote control unit, and replace the remote control unit if necessary.
  • L
    Lisa FarrellSep 15, 2025
    What does 'Internal error' mean on my Buderus Control Unit?
    • D
      David LongSep 15, 2025
      If your Buderus Control Unit displays an 'Internal error', it indicates an internal runtime error in the RC35. Replace the RC35 to resolve this issue.
  • A
    Alice HughesSep 6, 2025
    What causes an outside sensor defect in my Buderus Control Unit?
    • E
      Edwin BrownSep 6, 2025
      An outside sensor defect in your Buderus Control Unit can be caused by a few things. The sensor might be incorrectly connected or installed, there could be a break or short circuit in the sensor lead, or the sensor itself may be faulty. Check the sensor connection and the sensor lead. Ensure the sensor is correctly mounted and compare resistance values with the sensor characteristic curve.
  • R
    rebeccagarciaSep 3, 2025
    What does it mean when my Buderus Control Unit says 'Two master operating units in system'?
    • R
      Rodney MorganSep 3, 2025
      If your Buderus Control Unit displays 'Two master operating units in system', it means that both the RC20 and RC35 are registered as master units. To fix this, change parameter P1 in RC20 or remove RC35 from the EMS bus.

Summary

Guide to Instructions for Buderus Logamatic EMS RC35

Explanation of Symbols and Safety Instructions

Explanation of Symbols

Details warning symbols, signal words, and additional symbols used.

Safety Instructions for Operation

Provides crucial safety guidelines for installation, operation, and potential hazards.

Principles of Operation for the RC35

Setting the Operating Mode

Describes how to activate different operating modes (automatic, manual).

Permanent Room Temperature Settings

Explains how to set permanent day and night room temperatures.

Operation with the User Menu

Selecting the Operating Mode

Setting operating modes for RC35 and other heating circuits.

Setting the Switching Program

How to set heating schedules for day/night modes.

Troubleshooting the RC35 System

Frequently Asked Questions

Addresses common questions about system behavior and measurements.

Fault and Service Messages

Explains different types of messages displayed by the unit.

Resetting Faults and Errors

Procedures for resetting system faults and locking issues.

Buderus RC35 Specifications

General IconGeneral
DisplayLCD
Temperature ControlYes
Weather CompensationYes
CommunicationEMS Bus
MountingWall-mounted
Voltage24 V
Temperature range5°C to 30°C
Accuracy±0.5°C
Protection classIP20
Weight0.3 kg
Power consumption2 W
Switching currentNot applicable
Ambient temperature0°C to 45°C

Related product manuals