45
LED Error Codes:
If an operation error occurs, the info/error LED will ash red. It will alternate between ashing
for 1 second (tens digit) and 1/2 second (ones digit). Combine the number of longer ashes with
the number of shorter ashes to produce a two digit error code:
E00 - (no ashes) MPU failure
E01 - DRAM data line problem
E02 - DRAM address line problem
E03 - RTC chip error
E04 - failed to extract kernel
E06 - corrupted rmware
E07 - a hard disk was not found
E10 - UPS error
E11 - fan error
E15 - hard drive I/O error
E16 - no hard disks detected
E17 - internal controller error