5
REQUIRED REGULAR MAINTENANCE:
When performing Daily-Weekly Cleaning procedures, inspect o-rings, seals, and bushings for signs of wear or
damage and replace immediately.
Rinse once or twice daily or as required. On models IMIX-3, 4, 5, 3S+, & 5S+ a rinse reminder can be set using
the Rinse Alarm.
Check and/or replace every 6 months or as required:
32906.0001 Mixing Chamber Kit (Includes items indented below)
25732.0000 Steam Collector
25733.0003 Mixing Chamber
25734.0000 Whipper Chamber
25736.0000 Dispense Tip
24733.0010 O-ring
25902.0000 Frother
26356.0000 Shaft Seal
28866.0000 Receptacle
25903.0000 Elbow
Check and/or replace every 3 months or as required:
26356.1000 Whipper Shaft Seal Kit (Contains 6 Seals)
42032 060109